1-800-959-4014
Current switches
Larger version - 14K - Click A broad range of AC and DC current sensing devices with a variety of AC and DC contacts. Available with fixed and adjustable setpoints for underload and overload detection.

 

Model

 Ranges

Switch Type

Output

Data Sheets

Application, Features & Specs

AS1 Series 1-150A AC Sensing N.O. & N.C.

pdf

Specs
ASM Series 1.5 to 0-150A AC Sensing Self-calibrating N.O.

pdf

Specs
AS3 Series 1-6 to 40-175A AC Sensing 3 selectable ranges

pdf

One Pole Specs

Two Pole Specs

ASX Series 2-12 to 50-200 High Performance AC Sensing 3 selectable ranges

pdf

Specs
ASXP Series 1-20 or 20-50 High Performance AC Sensing SPST Relay

pdf

Specs
AM Series 1-6 to 100-200 Delay for over or undercurrent conditions N.O. & N.C.

pdf

Specs
AS0 Series 3-350 mA Low Current        AC Sensing N.O. & N.C.

pdf

Specs
DS3 Series 4-20 to 15-100A DC Sensing Hall effect technology

pdf

Specs


Current Operated Switches

Larger version - 23K - Click ‘AS1’ Current Switches from NK Technologies combine a current transformer, signal conditioner and limit alarm into a single package. The AS1 series has an extended current input range, universal solid-state outputs and a wide frequency response. Available in a split core case or two styles of solid core cases.

Application

  • Electronic Proof Of Flow
    — No need for pipe or duct penetrations.
    — More reliable than electromechanical pressure or flow switches.
  • Conveyors
    — Detects jams and overloads
    — Interlocks multiple conveyor sections
  • Lighting Circuits
    Easier to install and more accurate than photocells.
  • Electric Heaters
    Faster response than temperature sensors.

Features

  • Universal Output
    — Solid state switch N.C. or N.O. works on AC or DC to 240VAC.
    — Compatible with any automation system.
    — Reduces inventory, installation and engineering costs.
  • Self-powered
    Cuts installation and operating costs.
  • Easily Adjustable Setpoint
    Speeds startup
  • Solid or Split Core Case
    Choose the right version for each installation.
  • Built-in Mounting Bracket
    Provides the solid installation inspectors want.
  • UL, CUL and CE Approval
    Accepted worldwide.

Specifications
Power Supply None — Self-powered
Output Magnetically Isolated Solid-State Switch
Output Rating • N.O. Version: 0.2A @ 240VAC or VDC
• N.C. Version: 0.2A @ 130VAC or VDC
• Not polarity sensitive
Off State Leakage None
Response Time 0.120 Second Minimum
Setpoint Range • Fixed Core: 1–150A
• Split Core: 1.5–150A
Hysteresis 5% of Setpoint
Overload
Model Continuous 6 Sec 1 Sec
• –GO 250A 500A 1,000A (NOU)
• –GO 150A 400A 1,000A (NCU)
• All Other 150A 400A 1,000A
Isolation Voltage UL Listed to 1,270VAC, tested to 5,000VAC
Frequency Range 6–100Hz
Sensing Aperture • –FF Case : 0.55" (14mm) ID.
• –FT Case : 0.75" (19mm) ID.
• –SP Case : 0.85" (21.5mm) sq.
Case UL 94V-O Flammability rated
Environmental –58 to 149°F (–50 to 65°C),
0–95% RH, non-condensing
Listings UL 508 Industrial Control Equipment (USA & Canada), CE

^ back to top


Self-Calibrating Current Switches

Larger version - 13K - Click ‘ASM’ Current Switches from NK Technologies combine a current transformer, signal conditioner and self-calibrating limit alarm into a single package. The ASM Series has an extended current input range, universal solid-state outputs and a wide frequency response. Available in a split core or top terminal solid core case.

Applications

  • Conveyors (–OL option)
    — Detects jams and overloads.
    — Interlocks multiple conveyor sections.
  • Electronic Proof of Flow (–UL option)
    — No need for pipe or duct penetrations.
    — More reliable than electro-mechanical pressure or flow switches
  • Lighting or Heating Circuits (–UL option)
    Fast and easy installation.
  • Pump Protection (–OU option)
    Provides overload (jams) and underload (suction loss) indication.

Features

  • Self Calibrating Switch
    Speeds startup.
  • Self-powered
    Cuts installation costs.
  • Choose the Operating Style that Matches your Application
    • Status alarms on underload, proving that equipment is running properly.
    • Overload protects against jams and blockages.
    • Operating window provides both status and overload in a single device.
  • Universal Output
    AC or DC switching means compatibility with any automation system.
  • Compact
    Fits in starters and panels.
  • UL, CUL and CE Approval
    Accepted worldwide.

Specifications
Power Supply None — Self-powered
Output Magnetically Isolated Solid-State Switch
Output Rating • N.O. Version: 0.2 A @ 240VAC or VDC
• Not polarity sensitive
Off State Leakage
<10 microamps
Response Time 0.2 Second
Setpoint Range • 2.5–150A (Fixed Core)
• 2.8–150A (Split Core)
Setpoint • Overload : +15% of Load (–OL)
• Underload: –15% of Load (–UL)
• Operating Window: +/–15% of Setpoint
Hysteresis 5% of Setpoint
Overload Model  
 
Continuous 6 Sec 1 Sec
All 150A 500A 1,000A
Isolation Voltage UL Listed to 1,270VAC, tested to 5,000VAC
Frequency Range 6–100Hz
Sensing Aperture • –FT Case: 0.75" (19 mm) ID
• –SP Case: 0.85" (21.5mm) sq.
Case UL 94V-O Flammability rated
Environmental –58 to 149°F (–50 to 65°C),
0–95% RH, non-condensing
Listings UL 508 Industrial Control Equipment
(USA & Canada), CE (Pending)

^ back to top


Current Operated Switches

Larger version - 15K - Click ‘AS3’ Current Switches from NK Technologies combine a current transformer, signal conditioner and a limit alarm into a single package. The AS3 Series has three jumper selected current input ranges, solid-state AC or DC output and a wide frequency range. Available in a split core or front terminal solid core case.

Application

  • Electronic Proof of Flow
    — No need for pipe or duct penetrations.
    — More reliable than electro-mechanical pressure or flow switches.
  • Conveyors
    — Detects jams and overloads.
    — Interlocks multiple conveyor sections.
  • Lighting Circuits
    Easier to install and more accurate than photocells.
  • Electric Heaters
    Faster response than temperature sensors.

Features

  • Choice of Outputs
    — Solid state switch N.C. or N.O.
    — 1A @ 240VAC or 0.150 A @ 30VDC
    — 0.150 A @ 240VAC or DC (NO) 135VAC/DC (NC)
  • Self-powered
    —Cuts installation and operating costs.
  • Adjustable Setpoint
    —Speeds startup.
  • Solid or Split Core Case
    —Choose the right version for each installation.
  • Built-in Mounting Bracket
    —Provides the solid installation inspectors want.
  • UL, CUL and CE Approval
    —Accepted worldwide.

Specifications
Power Supply None — Self-powered
Output Isolated Solid State Switch
Output Rating Max. 1.0A @ 240VAC (AC Units), 0.15A@30VDC (DC Units)
15A @ 120VAC, 10A @ 240VAC (–15 Option)
Off State Leakage • NOAC: <10 microamps NODC  <10 microamps
• NCAC: 2.5mA              NCDC   1.4 mA
• AADC: <10 microamps CCDC    0.3 mA (NC term)
Response Time 0.04 to 0.120 Second
Setpoint Range • Fixed Core: 1–6, 6–40 & 40–175A
• Split Core: 1.5–6, 6–40 & 40–200A
Note: -15 option, AADC and CCDC available solid core ONLY
Hysteresis 5% of Setpoint
Overload
Range Continuous 6 Sec 1 Sec
• 1–6A 150A 400A 600A
• 6–40A 150A 500A 800A
• 40–175A 210A 800A 1,200A
Isolation Voltage UL listed to 1,270VAC, tested to 5,000VAC
Frequency Range 6–100Hz, works on VFDs
Sensing Aperture • –FF Case: 0.55" (14mm) ID.
• –SP Case: 0.85" (21.5mm) sq.
Case UL 94V-O Flammability Rated
Environmental –58 to 149°F (–50 to 65°C),
0–95% RH, non-condensing
Listings UL 508 Industrial Control Equipment
(USA & Canada), CE
Multi-pole Version (see below for description):
Switch Rating 0.15A @ 30VDC
Off State Leakage • AADC: <10 microamps
• CCDC: 0.3mA (NC terminal only)

^ back to top


Multi-pole Current Switches

AS3 Multiple pole output NK manufactures current switches that are a multi-pole version of the popular AS3 Series. The AS3 Series combines a current transformer, signal conditioner and two limit alarms into a single package. The AS3 Series has three jumper-selected current input ranges, solid-state DC output and a wide frequency range. Available in a front terminal solid core case.

Features

  • Multi-pole Output, <30VDC control only
    —Monitor two setpoints with one sensor.
  • Self-powered
    —Cuts installation and operating costs.
  • Easily Adjustable Setpoints
    —Speeds startup.
  • Solid  Core Case Only
    —Choose the right version for each installation.
  • Built-in Mounting Bracket
    —Provides the solid installation inspectors want.
  • UL, CUL and CE Approval
    —Accepted worldwide.

Applications

  • Pump Control
    Individually adjustable indication of overload (jam) and underload (suction loss).
  • Dual Alarm
    Easy setup for dual level alarms.

Specifications
See "AS3 Series" specifications and dimensional drawings

Multi-pole switches are available solid core only, DC switch capacity only

Switch Rating 0.15A @ 30VDC
Off State Leakage • AADC: <10 microamps
• CCDC: 0.3mA (NC terminal only)

^ back to top

Current Switches- Time Delay

ASX ‘ASX’ Current Switches from NK Technologies combine the universal output contact of the AS1series, and add the ability to change ranges with a jumper. The ASX Series is designed to provide a very precise set point adjustment, with constant hysteresis. Available in top terminal solid core or split core housings. Each model has a delay before action feature, allowing the contact to stay in the "shelf-state" condition during start up, and during momentary overload conditions.

Application

  • Electronic Proof of Flow
    — No need for pipe or duct penetrations.
    — More reliable than electro-mechanical pressure or flow switches.
  • Conveyors
    — Detects jams and overloads.
    — Interlocks multiple conveyor sections.
  • Small Motor Loads
    Reacts to small changes in current with constant hysteresis
  • Interlocking Machines
    Keeps all machines working together without extra wiring, even during low voltage episodes.

Features

  • Choice of Outputs
    — Solid state switch N.C. or N.O.
    — 1A @ 240VAC or 0.150 A @ 240VAC/DC
  • Self-powered
    —Cuts installation and operating costs.
  • Adjustable Setpoint and Time Delay
    —Speeds startup, allows for momentary overcurrent conditions.
  • Solid or Split Core Case
    —Choose the right version for each installation.
  • Built-in Mounting Bracket
    —Provides the solid installation inspectors want.
  • UL, CUL and CE Approval
    —Accepted worldwide.

Specifications
Power Supply None — Self-powered
Output Isolated Solid State Switch
Output Rating Max. 1.0A @ 240VAC (AC Units), or 0.15A@240VAC/DC
Off State Leakage • NOAC: <10 microamps
• NCAC: < 10 microamps            
• NOU/NCU
negligible
Response Time adjustable 0.2 to 15 Second
Setpoint Range • Fixed Core: 1.5–12, 12–55 & 50–200A
• Split Core: 2–12, 12–55 & 50–200A
Hysteresis 5% constant
Overload
Range Continuous 6 Sec 1 Sec
• 2–12A 150A 400A 600A
• 12–55A 150A 500A 800A
• 50–200A 210A 800A 1,200A
Isolation Voltage UL listed to 1,270VAC, tested to 5,000VAC
Frequency Range 50-100 Hz
Sensing Aperture • –FT Case: 0.75" (14mm) ID.
• –SP Case: 0.85" (21.5mm) sq.
Case UL 94V-O Flammability Rated
Environmental –58 to 149°F (–50 to 65°C),
0–95% RH, non-condensing
Listings UL 508 Industrial Control Equipment
(USA & Canada), CE

 


AC Powered Current Operated Switches

 ‘ASXP’ Current Switches from NK Technologies take our current operated switch selection to the next level. The ASXP Series has two models with different current input ranges. Utilizing a separate power source, either 120 or 24 VAC or DC, this product provides an SPST relay output rated at 10 amps. There is a factory set delay upon initial current inrush, allowing a simple connection to common controls without sensor actuation. The trip point can then be adjusted between 1 and 20 amps (ASXP1) or between 20 and 50 amps (ASXP2). Both models have adjustable delay before the relay energizes, up to 15 seconds, to allow for brief periods of over current conditions.

ApplicationASXP Series Installation

  • Conveyors
    Use as electronic shear pins
  • Overhead Hoists
    Alarms when hoist is overloaded
  • Machine Operation
    Instant status of motors, lamps and other loads.
  • Undercurrent Conditions
    Alarm when belts or couplings break

Features

  • Compact, One-piece Design
    —Fits in crowded motor starters, power supplies and control panels.
  • Input Isolation
    —Much simpler than CTs, signal conditioners and timing relays
  • Ranges Accommodate Most Common Motors
    —Single range can simplify installation
  • Tough
    —Designed to handle harsh industrial environments.
  • Motor Current Inrush Bypass Standard
    — Two seconds before switch output changes after initial startup
  • Built-in Mounting Bracket
    —Solid, secure mounting that inspectors want to see.
  • Dial Indication of Trip Point and Time Delay Settings

Specifications
Output Isolated dry contact
Output Rating • Relay: 10.0A @ 240VAC
Off State Leakage  None - Electromechanical relay
Response Time • 100mS (10% above Setpoint)
• Adjustable delay to 15 seconds
Setpoint Range 1-20 or 20-50 amps
Hysteresis 5% (Constant)
Overload • 500 amps (5 seconds)
Isolation Voltage 1.25 kV
Frequency Range 6-100Hz
Sensing Aperture 0.75" (19mm) diameter
Power Supply 120 or 24 VDC or VAC
Power Consumption 3VA
Case UL 94V-0 Flammability rated
Environmental • –4 to 122°F (–20 to 50°C), 0–95% RH, non-condensing
^ back to top
< Home

Motor Shield® Current Switch With Delay  

‘AM’ Current Switches from NK Technologies take our current operated switch selection to a refined level. The AM Series is available three models with different current input ranges. Utilizing the monitored current as a  power source, this product provides an AC solid state output rated to one amp, up to 240 VAC; or a solid state output that can control up to 150 mA, up to 30 VDC.

This sensor series can be produced so that the output changes only on current increase over the setpoint, or only on current decrease, or both over and under current conditions.

With the overload only models, there is an adjustable delay upon initial current inrush, allowing a simple connection to common controls without sensor actuation. The sensor output will change when the monitored circuit rises above a "floor" value of approximately one amp. The trip point can then be adjusted between 1 and 6 or 6 to 12 amps (AM1), between 12 and 25 or 25 and 50 amps (AM2)  or between 50 and 100 amps or 100 and 200 amps (AM3). All models have two adjustable delays before the output changes, up to 10 seconds. The first delays output during initial current inrush, and the second delays to allow for brief periods of over current conditions.

With the underload only models, there is an adjustable delay upon initial current inrush, allowing a simple connection to common controls without sensor actuation. The sensor output will change when the monitored circuit rises above a "floor" value of approximately one amp. The trip point can then be adjusted between 1 and 6 or 6 to 12 amps (AM1), between 12 and 25 or 25 and 50 amps (AM2)  or between 50 and 100 amps or 100 and 200 amps (AM3). All models have two adjustable delays before the output changes, up to 10 seconds. The first delays output during initial current inrush, and the second delays to allow for brief periods of over current conditions.

With the over/under models, there is one delay adjustable for over current, and the second for under current conditions. The sensor output will change when the monitored circuit current rises above the "low" setpoint, and will stay in that condition until the current exceeds the "high" setpoint. The trip points can then be adjusted between 1 and 6 or 6 to 12 amps (AM1), between 12 and 25 or 25 and 50 amps (AM2)  or between 50 and 100 amps or 100 and 200 amps (AM3).

Application                                 Overload

  • Conveyors
    Use as electronic shear pins

  • Overhead Hoists
    Alarms when hoist is overloaded

  • Machine Operation
    Instant status of motors, lamps and other loads.
  • Undercurrent Conditions
    Alarm when belts or couplings break

 

Features

  • Compact, One-piece Design
    —Fits in crowded motor starters, power supplies and control panels.
    Over-Under
  • Input Isolation
    —Much simpler than CTs, signal conditioners and timing relays
  • Ranges Accommodate Most Common Motors
    Dual ranges will allow use on many loads
  • Tough
    —Designed to handle harsh industrial environments.
  • Motor Current Inrush Bypass Standard
    Adjustable delay before switch output changes after initial startup
  • Built-in Mounting Bracket
    —Solid, secure mounting that inspectors want to see.

Specifications
Output Isolated solid state contact
Output Rating AC Models: 1.0A @ 240VAC

DC Models: 0.15A @ 30VDC

Off State Leakage AC: 3 ma @ 120 VAC

DC (NO): 1.1 mA @ 30 VDC, (NC) 1.4 mA @ 30 VDC

Response Time 120mS (10% above Setpoint)
• Adjustable delay to 10 seconds
Setpoint Range 1-6 & 6-12, 12-25 & 25-50 or 50-100 & 100-200 amps
Hysteresis •5% average across range
Overload • 500 amps (5 seconds)
Isolation Voltage 1.25 kV tested to 5 kV
Frequency Range 6-100Hz
Sensing Aperture 0.75" (19mm) diameter
Power Supply self powered from monitored circuit
Overhang time 0.50 seconds (time contact remains tripped after current decreases)
Case UL 94V-0 Flammability rated
Environmental • –5 to 158°F (–15 to 70°C), 0–95% RH, non-condensing
Listings • –UL Listed 508, C-UL and CE Certified
^ back to top
< Home

 


DC Current Operated Switches

DC Switch Application ‘DS3’ Current Switches from NK Technologies combine a Hall effect sensor, signal conditioner and a limit alarm into a single package. The DS3 Series has three jumper selected current input ranges and frequency response from DC to 400Hz. Available in a top terminal solid core case with either a relay output or a universal solid state output.

Application

  • Interlocking motor controls without aux. contacts
  • Power Supplies
    Signals over-current before equipment fails.
  • Machine Operation
    Instant status of motors, lamps and other loads.
  • Telecom Sites
    Monitors battery output.
  • Shunt Wound DC Motors
    Monitor the field windings to keep speed regulation under control

Features

  • Compact, One-piece Design
    Fits in crowded motor starters, power supplies and control panels.
  • Input Isolation
    Much safer than shunt/relay combinations.
  • Output Installation
    Isolated output greatly simplifies wiring.
  • Tough
    Designed to handle harsh industrial environments.
  • Adaptive Hysteresis
    — Hysteresis is 5% of setpoint.
    — Allows closer control than fixed hysteresis.
  • Reliable
    Solid state design, or electromechanical relay output.
  • Built-in Mounting Bracket
    Solid, secure mounting that inspectors want to see.

Specifications
Output Isolated dry contact
Output Rating • Solid State: 0.2A @ 240VAC/DC (N.O. Only)
• Relay: 5.0A @ 240VAC, 5.0A @ 30VDC (SPDT)
Off State Leakage <10 microamps (solid state)
Response Time • 100mS (10% above Setpoint)
• 20mS (100% above Setpoint)
Setpoint Range 4–20, 10–50 and 15–100A (DC)
Jumper select (derate by ÷2 for AC)
Hysteresis 5% of Setpoint
Overload Unaffected by sustained monitored current overloads
Isolation Voltage 3kV
Frequency Range DC to 400Hz
Sensing Aperture 0.75" (19mm) diameter
Power Supply 20–28VDC or VAC
Power Consumption 3VA
Case UL 94V-0 Flammability rated
Environmental • –4 to 122°F (–20 to 50°C), 0–95% RH, non-condensing
• –40 to 140°F (–40 to 60°C) (Solid State Output Only)
^ back to top
< Home

Low Current Operated Switches

AS0 low current operation AS0’ Current Switches from NK Technologies can be set to trip at any current level between 3 mA and 350 mA. NK has also made this sensor with trip points up to 1000 mA, so if you need a very fast operating, UL Listed current operated switch, let us know. This sensor can also be used in Canada as a ground fault sensor, due to the third party recognition issues with our AG series. NK makes models with normally open outputs (closing with current over the set point), and also with normally closed outputs (opening with current over the set point. The solid state output can be ordered to control up to one amp of AC current, up to 240 VAC, or with DC outputs capable of switching up to 0.15 amp up to 30 VDC.

Application As a ground fault sensor

  • Interlocking motor controls without aux. contacts
  • Power Supplies
    Signals over-current before equipment fails.
  • Machine Operation
    Instant status of motors, lamps and other loads.
  • Telecom Sites
    Monitors battery output.
  • Shunt Wound DC Motors
    Monitor the field windings to keep speed regulation under control

Features

  • Compact, One-piece Design
    Fits in crowded motor starters, power supplies and control panels.
  • Input Isolation
    Much safer than shunt/relay combinations.
  • Output Installation
    Isolated output greatly simplifies wiring.
  • Tough
    Designed to handle harsh industrial environments.
  • Adaptive Hysteresis
    — Hysteresis is 5% of setpoint.
    — Allows closer control than fixed hysteresis.
  • Reliable
    Solid state design, or electromechanical relay output.
  • Built-in Mounting Bracket
    Solid, secure mounting that inspectors want to see.

Specifications
Output Isolated dry contact
Output Rating • Solid State: 0.2A @ 240VAC/DC (N.O. Only)
• Relay: 5.0A @ 240VAC, 5.0A @ 30VDC (SPDT)
Off State Leakage <10 microamps (solid state)
Response Time • 100mS (10% above Setpoint)
• 20mS (100% above Setpoint)
Setpoint Range 4–20, 10–50 and 15–100A (DC)
Jumper select (derate by ÷2 for AC)
Hysteresis 5% of Setpoint
Overload • Unaffected by sustained monitored current overloads
Isolation Voltage 3kV
Frequency Range DC to 400Hz
Sensing Aperture 0.75" (19mm) diameter
Power Supply 20–28VDC or 98-105VAC
Power Consumption 3VA
Case UL 94V-0 Flammability rated
Environmental • –4 to 122°F (–20 to 50°C), 0–95% RH, non-condensing
• –40 to 140°F (–40 to 60°C) (Solid State Output Only)
^ back to top
< Home