PUMP MONITORING AND PROTECTION |
|
NK Technologies' family of current transducers, switches and power monitors produce outputs suitable for analog and digital meters, programmable logic controllers (PLC), distributed control systems (DCS), and digital or analog data recording devices. |
|
 Contactor PLC Indicator Light
|
|
|

|

Digital Meter PLCAC |
|
AC Current Switches are used on non-critical pumps to detect over- and under-current conditions. Available in N.O. or N.C. designs with optional time delays built in.
Setpoint Range: 1-150 Amps Output: Isolated Solid State Power Supply: None Self Powered Response Time: <120 ms Frequency: 6-100 Hz Isolation Voltage: 1,270 VAC Environmental: -40° to 133° F (-40° to 55° C), Typical Agency Approval: UL 508 (USA & Canada)*, CE
DC Designs Available * Most Models |
AC Current Switches Click here for more information. Over-current & Under-current Protection, Time Delay

|
|
AC Transducers Click here for more information. Current Monitoring, Load Measurement

|
AC Transducers are ideal for monitoring and recording the characteristics of pump motors. Analog outputs include 4-20 mA, 0-5 or 0-10 VDC for easy interface.
Input Range: 0-2000 Amp Output: 4-20 mA (True RMS Option), 0-5 or 0-10 VDC Response Time: < 300 ms, Typical Frequency: 10 to 400 Hz Accuracy: < 1.0% FS Environmental: 58° to 149° F (-50° to 65° C) Typical Agency Approval: UL 508 (USA & Canada)*, CE
DC Designs Available * Most Models |
|
|

|
|
|

PLC Shunt Trip Breaker |
Ground Fault Sensors Click here for more information. Ground Faults, Ground Fault Leakage, Safety Protection

|
|
Power Monitors Click here for more information. Load Monitoring, Dry Run Protection, Cavitation Detection

|
 PLC Digital Displays
|
|

|
Ground Fault Sensors offer a solution to monitor single or three phase pump motors.Sensitivities as low as 5 mA are available for personnel protection and 10-950 mA for machinery protection.
Inputs: Single or 3-phase Output: N.O. or N.C. Solid-state Switch or SPDT Form C Relay Latching or Non-latching Options Available Trip Points: 5/10/30 mA (jumper select) or 5-950 mA Adjustable Environmental: 5° to 158° F (-15° to 70° C) Agency Approval: UL 1053 Class 1 Recognized or UL 508*, CE
* Most Models |
|
Power Monitors are used for critical applications. These units are easily interfaced to control systems. They detect and monitor efficiency, dry run, cavitation and clogs.
Input Range: Single or 3-phase, 5-4000 A, 120-600 VAC Output Signal: kW & kWH (4-20 mA & 0-5 or 0-10 VDC), Power Factor, Frequency, Current, Voltage, kVA, Alarm Contact Accuracy: 0.5% FS, True RMS Power (+/- 0.5 Hz) Environmental: 0° to 122° F (-18° to 50° C) Agency Approval: UL 508 (USA & Canada)*, CE
* Most Models
|
 |