Monitor DC Current with New DT 3-Wire Current Transducer

Designed & Assembled in the USA

Home » current transducer

Monitor DC Current with New DT 3-Wire Current Transducer

  • Download Printer-Friendly Version

The newest addition to NK’s transducer family is in a very small, compact case with a 0-5 or 0-10 volt DC voltage output signal

The new DT Series 3-Wire Current Transducer from NK Technologies is specifically designed in a compact, space-saving case. The DT 3-Wire uses a common point for both power supply and output signal, and is factory calibrated for a single current range. This 3-wire method for DC current measurement keeps costs in check for projects where many sensors are needed. “Reliability is key in all monitoring applications, and there are gains in reliability whenever the number of connection points can be reduced,” explains Philip Gregory, President, NK Technologies. “With the addition of this new series of sensors, NK Technologies has provided the system designer even more choices to measure DC current.” The DT 3-Wire Current Transducer features industry standard outputs of 0-5 or 0-10 VDC proportional to the DC current. It is powered by 24 VDC, factory calibrated, and compact and easy to install. It’s commonly used in applications like photovoltaic panel monitoring, hoists, DC motor protection and wind driven generators. The DT Series complements NK Technologies’ existing DLT Series of 4-–20 mA current output sensors. When specified controllers can read only voltage output sensors, the DT 3-Wire provides the same space saving properties without the need to add an external dropping resistor, consequently removing another place where trouble could occur.

ATS Current Transducer/Switch Named a 2012 Plant Engineering Magazine Product of the Year Award Winner

ATS receives Silver award in the electrical controls category
The ATS Current Sensing Switch and Transducer from NK Technologies has received the Silver award for Electrical Controls in the 2012 Plant Engineering magazine Product of the Year contest. The ATS series is a compact one piece solution that combines a limit alarm with an analog output signal transducer to monitor produced or consumed AC current up to 1200 amps, while magnetically isolating outputs and inputs to maximize safety. An innovative and patent pending rotary switch makes it easy for users to set the trip point. DIN rail mounting simplifies installation and provides an extremely secure mount that is resistant to conductor movement.

View Press Release

Easily Monitor High AC Current Loads with the ATS Current Transducer/Switch

ATS monitors AC current up to 1200 amps and provides complete isolation between the primary circuit and controls in a single, compact package
NK Technologies introduces the ATS Current Sensing Switch and Transducer. The ATS series is a one piece solution that combines a limit alarm with an analog output signal transducer to monitor produced or consumed AC current up to 1200 amps, while magnetically isolating outputs and inputs to maximize safety. An innovative and patent pending rotary switch makes it easy for users to set the trip point. DIN rail mounting simplifies installation and provides an extremely secure mount that is resistant to conductor movement.

View Press Release

Easily Monitor DC Current with New DT Series Current Transducers

Large aperture design makes it easy to seamlessly monitor any circuit up to 1200 amps
NK Technologies introduces DT Series Large Aperture Current Transducers. The DT series combines a hall effect sensor and signal conditioner into a single package for use in DC current applications up to 1200 amps. Factory calibrated ranges simplify operation and eliminate zero and span pots. Industry standard 4-20mA, 0 – 5VDC or 0 – 10VDC outputs are magnetically isolated from the input to provide maximum safety, and eliminate insertion losses. Internal power regulation delivers reliable operation and helps keep installation costs low, even in applications with unregulated power. A DIN-rail mount enclosure makes installation easy..

View Press Release

New DLT Series Power Transducers Provide a Low-cost Alternative for Monitoring Photovoltaic Panels

The new DLT current transducers from NK Technologies are single range, take less panel space in combiner or re-combiner boxes, and produce a 4-20mA signal through a two wire loop, using nominal 24VDC in series with the output. As with all loop powered signals, they can be converted to 1-5 VDC or 2-10 VDC by the addition of a field installed resistor across the controller input terminals. The design saves time and cabling costs, as just two wires are used rather than four with previous designs.

View Application Note  View Data Sheet

 